Steel Cylinders R508b Refrigerant Replacement , Ac Refrigerant Recovery Tank

Steel Cylinders R508b Refrigerant Replacement , Ac Refrigerant Recovery Tank

Large Image :  Steel Cylinders R508b Refrigerant Replacement , Ac Refrigerant Recovery Tank

Product Details:
Place of Origin: CHINA
Brand Name: HengXiang
Certification: IOS9001,SGS,CE
Model Number: R508B
Payment & Shipping Terms:
Minimum Order Quantity: 10 sets
Price: negotiable
Packaging Details: Refillable steel cylinders : 5L/10L/40L/500L/ISO-TANK
Delivery Time: 30 working days
Payment Terms: T/T
Supply Ability: 100000 Tons per Year

Steel Cylinders R508b Refrigerant Replacement , Ac Refrigerant Recovery Tank

Description
Classification: Alkene & Derivatives Other Names: Mixed Refrigerant
ODP: 0 Appearance: Colorless And Clear
Application: Refrigerations And Chemical Industry Material Type: Eco-friendly Refrigerant
Grade Standard: Agriculture Grade, Electron Grade, Industrial Grade, Medicine Grade
High Light:

Steel Cylinders R508b Refrigerant Replacement

,

R508b Refrigerant Replacement

,

R508b ac refrigerant recovery tank

Mixed Refrigerant 

 

R508B

 

Purity ≥99.9%              Water ≤10 PPm

Acidity ≤ 0.1 PPm        Vapor Residue≤ 100 PPm

 

Physical Properties

 

Chemical Formula   Molecular Mass 95.394
Boiling Point (1atm/℃) -87.4 Critical Temperature (℃) 11.205
Critical Pressure (Mpa) 3.772 Critical Density (g/cm3) 0.5684
ODP 0 GWP 12000

 

Packing

 

Refillable steel cylinders 5L/10L/40L/500L/ISO-TANK

 

Application

 

The widespread use of ultra low temperature refrigerant, mainly used in environmental test box/equipment, freeze-drying machine/freeze dryer, ultra low temperature refrigera-tor, biochemical test box and cryogenic equipment, rare for the cascade refrigeration system for low temperature stage. R508b refrigeration temperature can drop to -80℃ or below , meeting the industry standard R-13, R-503 and R-23 long-term substitute, it is completely adapted to the R-503 working environment.

R508B is a widely used ultra-low temperature refrigerant. Due to its good comprehensive properties, R508B is a very effective and safe CFC-13 (R13, R-13, Freon 13, Freon-13), R-503 and HFC- 23 (R23, R-23, Freon 23, Freon-23) alternatives, mainly used in environmental test chambers / equipment (cold heat impact tester), freeze dryer / freeze dryer, ultra-low temperature refrigerator or freezer, blood bank refrigerator In cryogenic equipment such as biochemical test chambers (including scientific research refrigeration, medical refrigeration, etc.), the low temperature grades used in these cascade refrigeration systems are common. R508B cooling temperature can be reduced to -80 ° C or even lower, is a long-term replacement of industry-standard R-13, R-503 and R-23, it is fully adapted to the R-503 working environment. Although R508B refrigerant is the most popular alternative to Freon R-503 and R13 in new ultra-low temperature refrigeration equipment, but because R508B and R503, R13 physical and chemical properties, theoretical cycle performance and compressor oil are not the same, so for the initial installation For the after-sales maintenance of R503 and R13 refrigerant refrigeration equipment, if you need to add or replace the refrigerant, you can only add R503 and R13, usually can not directly replace R503, R13 with R508B (that is usually can not be exchanged).

 

Introductions

 

R-508B is an environmentally friendly azeotropic refrigerant that is completely free of ozone-depleting CFC and HCFC substances. It has been approved and recommended by most of the world’s most popular cryogenic environmentally friendly refrigerants. It is widely used in new refrigeration equipment (ultra-low temperature, copious cooling) on the initial installation and maintenance process. It meets the standards of the US Environmental Protection Agency EPA, SNAP and UL, and meets the A1 safety rating category of the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) (this is the highest level and is harmless to humans).

 

Handling & Storage

 

refrigerant cylinder is a pressurized container, which should be stored away from fire, heat source, avoid direct sunshine, and usually stored in a cool, dry and ventilated warehouse. When handling, it should be lightly loaded and unloaded to prevent damage to cylinders and valve accessories.

 

Steel Cylinders R508b Refrigerant Replacement , Ac Refrigerant Recovery Tank 0Steel Cylinders R508b Refrigerant Replacement , Ac Refrigerant Recovery Tank 1

Contact Details
Xiamen Hengxiang Refrigeration Equipment Co., Ltd.

Contact Person: Mrs. Iris

Tel: +86 13779992296

Fax: 86--5093216

Send your inquiry directly to us (0 / 3000)